Post Tender Report TR148 April 2022 CSV EXT

Data Explorer

Data Explorer

Table Information

Tender Ref

Title Tender Ref
Type string
Description A reference to identify the tender submission. The first 3 digits giver the tender round, and the following digits ID the tender submission within the tender round.
Comment
Example 122.001
Unit

Status

Title Status
Type string
Description This indicates whether the tender was accepted or rejected during the assessment process.
Comment
Example
Unit

Rejection Codes

Title Rejection Code
Type string
Description For tenders with the ‘rejected’ status, these codes give a reason as to why they were rejected.
Comment A reference for these codes can be found below the table in this file, or in the FFR market information reports.
Example 2
Unit

Company Name

Title Company Name
Type string
Description The name of the company which submitted the associated tender.
Comment
Example Example company
Unit

Tendered Unit (BMU/Unit ID)

Title Tendered Unit (BMU/Unit ID)
Type string
Description The name of the unit for which the associated tender was submitted. This can be a BMU ID or Unit ID for non-BMUs.
Comment
Example Ex-FFR-1
Unit

TO connection / DNO connection

Title TO connection / DNO connection
Type string
Description Indicates whether the unit is connected to the transmission network or the distribution network.
Comment
Example TO connection
Unit

Generation Type

Title Generation type
Type string
Description Indicates the fuel type of the tendered unit.
Comment
Example Wind
Unit

Start Date

Title Start date
Type string
Description The date from which FFR would be provided following acceptance of the tender.
Comment
Example 29/02/2020
Unit

End Date

Title End date
Type string
Description The final date for which FFR would be provided following acceptance of the tender.
Comment
Example 31/03/2020
Unit

Tendered Period (dd.mm.yy - dd.mm.yy)

Title Tendered period (dd.mm.yy – dd.mm.yy)
Type string
Description The date range for which FFR would be provided as per the tender submission.
Comment
Example 29.02.20 - 31.03.20 (1 months)
Unit

Applicable FFR Capability Data Table

Title Applicable FFR Capability Data Table
Type string
Description A reference to where information on the technical parameters of the tendered unit is accessible for National Grid ESO.
Comment
Example As per FFR framework agreement
Unit

Tendered Frames per Service Day - From (Mon-Fri)

Title Tendered Frames per Service Day - from
Type string
Description The time from which the unit would be available to provide FFR
Comment Has to be a time consistent with EFA blocks
Example 2300
Unit

Tendered Frames per Service Day - To (Mon- Fri)

Title Tendered Frames per Service Day - to
Type string
Description The time from which the unit would stop being available to provide FFR
Comment Has to be a time consistent with EFA blocks
Example 700
Unit

Tendered Frames per Service Day - Duration (Mon-Fri)

Title Tendered Frames per Service Day - duration (h)
Type string
Description The duration per day for which the unit would be available to provide FFR
Comment
Example 8
Unit hours

Tendered Frames per Service Day - From (Saturday)

Title Saturdays From
Type string
Description start time for Saturdays, must begin in line with EFA block timings
Comment select from drop down
Example
Unit

Tendered Frames per Service Day - To (Saturday)

Title Saturdays To
Type string
Description End time for Saturdays, must begin in line with EFA block timings
Comment select from drop down
Example
Unit

Tendered Frames per Service Day - Duration (Saturday)

Title Duration (h)
Type string
Description number of hours that have been tendered for Saturdays
Comment total hours
Example
Unit

Tendered Frames per Service Day - From (Sunday/Bank Holidays)

Title Sundays/ Bank Holidays From
Type string
Description start time for Sundays/ bank holidays, must begin in line with EFA block timings
Comment select from drop down
Example
Unit

Tendered Frames per Service Day - To (Sunday/Bank Holidays)

Title Sundays/ Bank Holidays To
Type string
Description End time for Sundays/ bank holidays, must begin in line with EFA block timings
Comment select from drop down
Example
Unit

Tendered Frames per Service Day - Duration (Sunday/Bank Hol)

Title Duration (h)
Type string
Description number of hours that have been tendered for Sundays/ bank holidays
Comment total hours
Example £0.00
Unit £

Tendered Prices - Availability Fee (£/h)

Title Availability fee
Type string
Description This is the main fee that all providers will tender in.  It is the number of hours of availability from a provider.
Comment
Example 100
Unit £/h

Tendered Prices - Nomination Fee (£/h)

Title Nomination fee
Type string
Description Upon a tender being accepted, National Grid ESO can choose to nominate all or part of the hours tendered in. This payment is made for each hour nominated.
Comment
Example 600
Unit £/h

Tendered Prices - Window Initiation Fee (£/window)

Title Window initiation fee
Type string
Description Fee for each FFR window that the provider has been instructed under
Comment
Example
Unit £/window

BMUs Only

Title BMUs only – Applicable Balancing Service (ABSVD)
Type string
Description A yes/no field depending on whether ABSVD applies to the tendered unit. This can only apply to BMUs.
Comment
Example YES
Unit

Maximum Part Load Point (MW)

Title Maximum part load point
Type string
Description The maximum partial load the unit can run with - a unit is part-loaded if it is operating at a level other than
Comment
Example 4
Unit MW

Minimum Part Load Point (MW)

Title Minimum part load point
Type string
Description The minimum partial load the unit can run with - a unit is part-loaded if it is operating at a level other than
Comment
Example 0
Unit MW

Minimum MEL (MW)

Title Minimum Maximum Export Limit
Type string
Description The minimum value for the MEL. The MEL is the profile of the maximum level at which the BM Unit may be exporting (in MW) to the GB Transmission System at the Grid Entry Point or Grid Supply Point as appropriate
Comment
Example 45
Unit MW

Maximum SEL (MW)

Title Maximum Stable Export Limit
Type string
Description The maximum value for the SEL. The SEL is the minimum value at which the BM Unit, under stable conditions, may export (in MW) to the GB Transmission System at the Grid Entry Point or Grid Supply Point as appropriate
Comment
Example 4
Unit MW

Primary Response (max.) @ 0.2Hz (MW)

Title Primary response (max) @ 0.2Hz (MW)
Type string
Description The amount (in MW) of primary frequency response that will be provided at frequency deviations at 0.2 Hz respectively.
Comment
Example 8
Unit MW

Primary Response (max.) @ 0.5Hz (MW)

Title Primary response (max) @ 0.5Hz (MW)
Type string
Description The amount (in MW) of primary frequency response that will be provided at frequency deviations at 0.5 Hz respectively.
Comment
Example 20
Unit MW

Primary Response (max.) @ 0.8Hz (MW)

Title Primary response (max) @ 0.8Hz (MW)
Type string
Description The amount (in MW) of primary frequency response that will be provided at frequency deviations at 0.8 Hz respectively.
Comment
Example 1
Unit MW

Secondary Response (max.) @ 0.2/0.2Hz (MW)

Title Secondary response (max) @ 0.2Hz (MW)
Type string
Description The amount (in MW) of secondary frequency response that will be provided at frequency deviations at 0.2 Hz respectively.
Comment
Example 0.4
Unit MW

Secondary Response (max.) @ 0.5/0.5Hz (MW)

Title Secondary response (max) @ 0.5Hz (MW)
Type string
Description The amount (in MW) of secondary frequency response that will be provided at frequency deviations at 0.5 Hz respectively.
Comment
Example 20
Unit MW

High Frequency Response (max.) @ 0.2Hz (MW)

Title High frequency response (max) @ 0.2Hz (MW)
Type string
Description The amount (in MW) of high frequency response that will be provided at frequency deviations at 0.2 Hz respectively.
Comment
Example 8
Unit MW

High Frequency Response (max.) @ 0.5Hz (MW)

Title High frequency response (max) @ 0.5Hz (MW)
Type string
Description The amount (in MW) of high frequency response that will be provided at frequency deviations at 0.5 Hz respectively.
Comment
Example 1
Unit MW

Are you adding volume as per detail change provision

Title Adding volume
Type string
Description An indication as to whether volume is being added to a previous tender via this one
Comment
Example Yes
Unit

Please state the accepted tender that you are stacking onto

Title Stacked tender
Type string
Description The tender being stacked on as per the previous column
Comment
Example 122.156
Unit

Please state if this is an all or nothing bid.

Title All or nothing bid
Type string
Description Whether or not this bid is part of an all or nothing combination of bids
Comment
Example
Unit

Please indicate if this is a mutually exclusive tender

Title Mutually exclusive tender
Type string
Description Any bids with which this one cannot be taken
Comment
Example Cannot be accepted with B
Unit

Automatic Response Energy Deliverable by 10s (MW)

Title Non-dynamic response volumes
Type string
Description The amount of automatic response (in MW) to be delivered within 10s of the frequency dropping below 49.7 Hz.
Comment
Example 10
Unit MW

Automatic Response Energy Deliverable by 30s (MW)

Title Non-dynamic response volumes
Type string
Description The amount of automatic response (in MW) to be delivered within 30s of the frequency dropping below 49.7 Hz.
Comment
Example 20
Unit MW

Post code

Title Tendered Unit Post code
Type string
Description 1st 4 digits of the assets postcode. Only applies to assets 1MW or greater in size. For aggregated assets initially this will list the largest asset if over 1MW
Comment
Example ZX0 9
Unit

Comments

Title Comments
Type string
Description Any further comments associated with the tender submission.
Comment
Example H for only 90 mins
Unit